Indoor Unit
CS-ME7QKUA
Destination
U.S.A.
Canada
Please file and use this manual together with the service manual for Model No. CU-5E36QBU, Order No. PAPAMY1312037CE.
PRECAUTION OF LOW TEMPERATURE
In order to avoid frostbite, be assured of no refrigerant leakage during the installation or repairing of refrigerant circuit.
WARNING
This service information is designed for experienced repair technicians only and is not designed for use by the general public.
It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product.
Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to
service or repair the products dealt with in this service information by anyone else could result in serious injury or death.
Przeglądanie stron 0
1 2 3 4 5 6 ... 67 68

Podsumowanie treści

Strona 1 - Order No: PAPAMY1312045CE

© Panasonic Corporation 2013 Order No: PAPAMY1312045CE Indoor Unit CS-ME7QKUADestinationU.S.A.Canada Please file and use this manual together w

Strona 2 - TABLE OF CONTENTS

10 6. Refrigeration Cycle Diagram

Strona 4

12 8. Wiring Connection Diagram 8.1 Indoor Unit

Strona 5 - 2. Specification

13 9. Electronic Circuit Diagram 9.1 Indoor Unit

Strona 6

14 10. Printed Circuit Board 10.1 Indoor Unit 10.1.1 Main Printed Circuit Board

Strona 7 - 3. Features

15 10.1.2 Power Printed Circuit Board 10.1.3 Indicator Printed Circuit Board

Strona 8 - 4.3 Remote Control

16 11. Installation Instruction 11.1 Select the Best Location 11.1.1 Indoor Unit  Do not install the unit in excessive oil fume area such as kitche

Strona 9 - 5. Dimensions

17 11.2 Indoor Unit 11.2.1 How to Fix Installation Plate The mounting wall shall be strong and solid enough to prevent it from the vibration. The

Strona 10

18 11.2.3 Indoor Unit Installation 11.2.3.1 For the right rear piping 11.2.3.2 For the right bottom piping 11.2.3.3 For the embedded piping

Strona 11 - 7. Block Diagram

19 11.2.4 Connect the Cable to the Indoor Unit 1. The inside and outside connection cable can be connected without removing the front grille. 2.

Strona 12 - 8. Wiring Connection Diagram

2 TABLE OF CONTENTS 1. Safety Precautions ... 3 2. Specification ...

Strona 13 - 9.1 Indoor Unit

20 11.2.5 Wiring Stripping and connecting requirement 11.2.5.1 Cutting and flaring the piping 1 Please cut using pipe cutter and then remove the

Strona 14 - 10. Printed Circuit Board

21 12. Operation Control 12.1 Basic Function Inverter control, which equipped with a microcomputer in determining the most suitable operation mode as

Strona 15

22 12.1.4.2 Automatic Operation  This mode can be set using remote control and the operation is decided by remote control setting temperature, remot

Strona 16 - 11. Installation Instruction

23 [Heating] o According to indoor pipe temperature, automatic heating fan speed is determined as follows.  Feedback control o Immediately after

Strona 17 - 11.2 Indoor Unit

24 12.4.2 Horizontal Airflow The horizontal airflow direction louvers can be adjusted manually by hand. 12.5 Quiet Operation (Cooling Mode/Cooling

Strona 18

25  Control contents o Fan speed auto  Indoor FM RPM depends on pipe temperature sensor of indoor heat exchanger. Auto fan speed is changed from n

Strona 19

26 12.10 Indication Panel Note:  If POWER LED is blinking, the possible operation of the unit are Hot Start, during Deice operation, operation

Strona 20

27 13. Operation Control (For Multi Split Connection) During multi split connection, indoor unit’s operation controls are same with single split conn

Strona 21 - 12. Operation Control

28  For the 2nd judgment onwards o If indoor intake temperature - remote control setting temperature  5.4°F, if previous operate in DRY mode, then

Strona 22 - 12.1.4.2 Automatic Operation

29 14. Servicing Mode 14.1 Auto Off/On Button 1 AUTO OPERATION MODE The Auto operation will be activated immediately once the Auto OFF/ON button i

Strona 23 - 12.4 Airflow Direction

3 CAUTION WARNINGWARNING 1. Safety Precautions  Read the following “SAFETY PRECAUTIONS” carefully before perform any servicing.  Electrical work m

Strona 24 - 12.4.2 Horizontal Airflow

30 4 REMOTE CONTROL RECEIVING SOUND OFF/ON MODE The Remote Control Receiving Sound OFF/ON Mode will be activated if the Auto OFF/ON button is pressed

Strona 25 - 12.9 Auto Restart Control

31 15. Troubleshooting Guide 15.1 Refrigeration Cycle System In order to diagnose malfunctions, make sure that there are no electrical problems befor

Strona 26 - 12.10 Indication Panel

32 15.1.1 Relationship between the condition of the air conditioner and pressure and electric current  Carry out the measurements of pressure, ele

Strona 27 - 13.4 Automatic Operation

33 15.2 Breakdown Self Diagnosis Function 15.2.1 Self Diagnosis Function (Three Digits Alphanumeric Code)  Once error occurred during operation, t

Strona 28 - 13.8 Indication Panel

34 15.3 Error Code Table

Strona 29 - 14. Servicing Mode

35 Note: “○” – Frequency measured and fan speed fixed The memory data of error code is erased when the power supply is cut off, or press the Auto Sw

Strona 30 - 14.2 Remote Control Button

36 15.4 Self-diagnosis Method 15.4.1 H11 (Indoor/Outdoor Abnormal Communication) Malfunction Decision Conditions  During startup and operation of c

Strona 31 - 15. Troubleshooting Guide

37 15.4.2 H12 (Indoor/Outdoor Capacity Rank Mismatched) Malfunction Decision Conditions  During startup, error code appears when different types of

Strona 32

38 15.4.3 H14 (Indoor Intake Air Temperature Sensor Abnormality) Malfunction Decision Conditions  During startup and operation of cooling and heati

Strona 33 - 15.2.2 To Make a Diagnosis

39 15.4.4 H15 (Compressor Temperature Sensor Abnormality) Malfunction Decision Conditions  During startup and operation of cooling and heating, the

Strona 34 - 15.3 Error Code Table

4 CAUTION19. During installation, install the refrigerant piping properly before run the compressor. (Operation of compressor without fixing refrigera

Strona 35

40 15.4.5 H16 (Outdoor Current Transformer Open Circuit) Malfunction Decision Conditions  A current transformer (CT) is detected by checking the co

Strona 36 - 15.4 Self-diagnosis Method

41 15.4.6 H19 (Indoor Fan Motor – DC Motor Mechanism Locked) Malfunction Decision Conditions  The rotation speed detected by the Hall IC during fan

Strona 37

42 15.4.7 H23 (Indoor Pipe Temperature Sensor Abnormality) Malfunction Decision Conditions  During startup and operation of cooling and heating, th

Strona 38

43 15.4.8 H27 (Outdoor Air Temperature Sensor Abnormality) Malfunction Decision Conditions  During startup and operation of cooling and heating, th

Strona 39

44 15.4.9 H28 (Outdoor Pipe Temperature Sensor Abnormality) Malfunction Decision Conditions  During startup and operation of cooling and heating, t

Strona 40

45 15.4.10 H30 (Compressor Discharge Temperature Sensor Abnormality) Malfunction Decision Conditions  During startup and operation of cooling and h

Strona 41

46 15.4.11 H32 (Outdoor Heat Exchanger Temperature Sensor 2 Abnormality) Malfunction Decision Conditions  During startup and operation of cooling a

Strona 42

47 15.4.12 H33 (Unspecified Voltage between Indoor and Outdoor) Malfunction Decision Conditions  The supply power is detected for its requirement b

Strona 43

48 15.4.13 H36 (Outdoor Gas Pipe Sensor Abnormality) Malfunction Decision Conditions  During startup and operation of cooling and heating, the temp

Strona 44

49 15.4.14 H37 (Outdoor Liquid Pipe Temperature Sensor Abnormality) Malfunction Decision Conditions  During startup and operation of cooling and he

Strona 45

5 2. Specification Model Indoor CS-ME7QKUA Outdoor CU-5E36QBU Performance Test Condition ARI Power Supply Phase, Hz Single, 60 V 208 230 Min. Mi

Strona 46

50 15.4.15 H97 (Outdoor Fan Motor – DC Motor Mechanism Locked) Malfunction Decision Conditions  The rotation speed detected by the Hall IC during f

Strona 47

51 15.4.16 H98 (Indoor High Pressure Protection) Error Code will not display (no Timer LED blinking) but store in EEPROM Malfunction Decision Condit

Strona 48

52 15.4.17 H99 (Indoor Freeze Prevention Protection: Cooling or Soft Dry) Malfunction Decision Conditions  Freeze prevention control takes place (w

Strona 49

53 15.4.18 F11 (Indoor Pipe Temperature Sensor Abnormality) Malfunction Decision Conditions  When cooling operation, when indoor pipe temperature o

Strona 50

54 15.4.19 F17 (Indoor Standby Units Freezing Abnormality) Malfunction Decision Conditions  When the different between indoor intake air temperatur

Strona 51

55 15.4.20 F90 (Power Factor Correction Protection) Malfunction Decision Conditions  During startup and operation of cooling and heating, when Powe

Strona 52

56 15.4.21 F91 (Refrigeration Cycle Abnormality) Malfunction Decision Conditions  During cooling, compressor frequency = Fcmax.  During cooling a

Strona 53

57 15.4.22 F93 (Compressor Rotation Failure) Malfunction Decision Conditions A compressor rotation failure is detected by checking the compressor run

Strona 54

58 15.4.23 F95 (Cooling High Pressure Abnormality) Malfunction Decision Conditions During operation of cooling, when outdoor unit heat exchanger high

Strona 55

59 15.4.24 F96 (IPM Overheating) Malfunction Decision Conditions During operating of cooling and heating, when IPM temperature data (212°F) is detecte

Strona 56

6 Model Indoor CS-ME7QKUA Outdoor CU-5E36QBU Drain Hose Inner Diameter mm (inch) 16.7 (5/8) Length mm (inch) 650 (25-5/8) Indoor Heat Exchanger Fi

Strona 57

60 15.4.25 F97 (Compressor Overheating) Malfunction Decision Conditions During operation of cooling and heating, when compressor tank temperature dat

Strona 58

61 15.4.26 F98 (Input Over Current Detection) Malfunction Decision Conditions During cooling and heating operation, when an input over-current (16.8A)

Strona 59

62 15.4.27 F99 (Output Over Current Detection) Malfunction Decision Conditions During operation of cooling and heating, when an output over-current (

Strona 60

63 WARNING16. Disassembly and Assembly Instructions High Voltage is generated in the electrical parts area by the capacitor. Ensure that the capac

Strona 61

64 16.1.1.2 To remove discharge grille

Strona 62 - Abnormal resistance 0 or ∞

65 16.1.1.3 To remove control board 16.1.1.4 To remove cross flow fan and indoor fan motor

Strona 64

67 17. Exploded View and Replacement Parts List 17.1 Indoor Unit Note The above exploded view is for the purpose of parts disassembly and replaceme

Strona 65

68 SAFETY REF. NO. PART NAME & DESCRIPTION QTY. CS-ME7QKUA REMARK 1 CHASSIS COMPLETE 1 CWD50C1633 2 FAN MOTOR 1 L6CBYYYL0055 O 3

Strona 66

7 3. Features  Inverter Technology o Wider output power range o Energy saving o Quick Cooling o More precise temperature control  Environment

Strona 67 - 17.1 Indoor Unit

8 4. Location of Controls and Components 4.1 Indoor Unit 4.2 Outdoor Unit 4.3 Remote Control

Strona 68

9 5. Dimensions 5.1 Indoor Unit

Komentarze do niniejszej Instrukcji