Podsumowanie treści

Strona 1 - WJ-MP204C

Before attempting to connect or operate this product,please read these instructions carefully and save this manual for future use.Model No. WJ-MP204CD

Strona 2 - ENGLISH VERSION

10Shown below are some system connection examples using Data Multiplex unit with peripheral devices in PS•Data (PanasonicSecurity Data) or the Camera

Strona 3 - IMPORTANT SAFETY INSTRUCTIONS

11● Multi-unit Connection (PS•Data)A maximum of four units can be connected in a daisy fashion, from SPOT OUT to SPOT IN and so on, and finally from S

Strona 4 - CONTENTS

12SD RDIN INCAMERA RS485ABABGVS/VDSPOT DATAALARM / REMOTEMODESIGNAL GND4321OUT OUTINOUT4321TRIN INCAMERA RS485ABABGVS/VDSPOT DATAALARM / REMOTEMODESIG

Strona 5 - FEATURES

13ONOFFPOWERREMOTOTIMEROPERATEFULLHDDSEQUENCESETLOCKALARMALARMRESETALARMSUSPENDMULTISCREENSELECTSET UP/ESCGROUPSELECTSPOTMULTISCREENDAYLIGHT SAVINGSEL

Strona 6 - PRECAUTIONS

14● Matrix Switcher Connection (Camera Communication)The WJ-SX350 and WV-CU360C are typically combined with the WJ-MP204C when using the Camera Commun

Strona 7 - ■ Front View

15OFFSW positionVS/VD● Unit Number SettingA rotary switch is placed on the front panel. It specifies the WJ-MP204C unit number in a PS•Data protocol s

Strona 8 - ■ Rear View

168 PS•DataAddress Assignment8 Camera Communication ProtocolAs shown in the table, the UNIT switch determines the camera unit numbers. Address Assignm

Strona 9 - INSTALLATION

178 Alarm input Available when TERMINAL is set to ALARM and TERM. ALARM is set to ON in the setup, and the internal connector remains inthe default po

Strona 10 - CONNECTION & SETTING

18• Basic Connection• Daisy Connection● RS-485 Terminal Connection (CameraCommunication)These terminals are connected with system devices usingthe Cam

Strona 11 - ● Multi-unit Connection (PS

19 Prior to setup● Confirmation1. Connections and switch settings are complete.2. Switch on the power of the connected system devicesincluding the mo

Strona 12 - Control Site

2The serial number of this product may be found on the bot-tom of the unit.You should note the serial number of this unit in the spaceprovided and ret

Strona 13 - Data Multiplex Unit WJ-MP204

20● Setup menusThere are two setup menu groups depending on the communication protocol used in the system, menus for PS•Data and forthe Camera Communi

Strona 14 - SIGNAL GND

21 Setup Menus for PS•Data● Communication setup (PS•Data)Communication parameters for a PS•Data protocol systemare set in this menu.1. Hold down the

Strona 15 - ● DIP Switch Setting

228 Alarm mode setup 1. Move the cursor to ALARM MODE to select ON or OFFwith the [–] or [+] button, then press SET. The defaultsetting is ON.ON : Ope

Strona 16 - 9876 54321

238 Cable compensation/VD2 sync/data setupThe COMP/VD2/DATA menu is displayed when you select itin the SYSTEM menu.In this menu, each camera is set up

Strona 17 - ● Internal Setting

248 Camera ConfigurationThe CAMERA CONFIG menu is displayed when you selectit in the SYSTEM menu.When more than one unit are used, each camera input i

Strona 18 - Communication)

258 CAM ADDRESSCamera addresses are assigned to each of the unit's cam-era input.1. Move the cursor to CAM ADDRESS , then pressSET. The CAM ADDR

Strona 19 - System Controller

26The ALARM MODE sub menu appears.1. Move the cursor to MONITOR SPOT to select ON orOFF with the [–] or [+] button. The default setting is ON.This set

Strona 20 - ● Setup menus

272. Move the cursor to COMP. Select a parameter with the[–] or [+] button. The default setting is S.The longer a coaxial cable is extended, the more

Strona 21 - ■ Setup Menus for PS

28Camera selection and alarm operations are made on thefront panel of the unit or WV-CU360C System Controller. Camera Selection● Front Panel Operatio

Strona 22 - 8 Alarm mode setup

29WJ-MP204CFunction WV-CU360CCamera Selection● Alarm ResetAlarms are reset according to the reset mode (EXT, auto (1S-5M) or OFF) selected in the ALAR

Strona 23 - 8 VS/VD input setup

3IMPORTANT SAFETY INSTRUCTIONS1) Read these instructions.2) Keep these instructions.3) Heed all warnings.4) Follow all instructions.5) Do not use this

Strona 24 - Communication Protocol

30SPECIFICATIONSPower Source : 120 V AC 60 HzPower Consumption : 7 WCamera Input : 1 V[p-p]/75 Ω x 4Spot Input : 1 V[p-p]/75 Ω x 1VS/VD Input : VS (1

Strona 25 - ● System setup

31STANDARD ACCESSORIESSwitch Protector ... 1 pc.ALL RESETThe Data Multiplex Unit W

Strona 26

N1001-0 V8QA5877AN Printed in JapanN 192001 © Matsushita Communication Industrial Co., Ltd. All rights reserved.Panasonic Canada Inc.5770 Ambler Driv

Strona 27 - 8 Terminal Mode

4CONTENTSIMPORTANT SAFETY INSTRUCTIONS ...

Strona 28 - OPERATION

5PREFACEFEATURESThe Data Multiplex Unit WJ-MP204C is designed for instal-lation in a surveillance system, offering system flexibilityparticularly when

Strona 29 - ALM SUSPEND

6PRECAUTIONS• Refer all work related to the installation of thisproduct to qualified service personnel or systeminstallers.• Do not block the ventilat

Strona 30 - SPECIFICATIONS

7MAJOR OPERATING CONTROLS AND THEIR FUNCTIONSq Power switch and power Indicator (POWER ON OFF)To turn on or off the power of the unit, press the switc

Strona 31 - ALL RESET

8 Rear View@1 Camera Input Connector 1-4 (CAMERA IN 1 2 3 4)These connectors accept the composite video signalsupplied by the cameras while passing t

Strona 32

9Joint metalRemove 2 screws from the rear beforehand.Rack mountingbracket (small)Rack mountingbracket (small) Mount screw Binding head (M3x8)Mount scr