List of Error Codes
If a problem occurs with your hardware, [POST Start up Error(s)] is displayed along with
the error code(s), follow the on-screen instructions.
Setup: Setup Utility (Cépage 73) is started. Run [Load Default Settings (Non-PnP)].
Rerun the Setup Utility to input the appropriate operating environment
settings.
Exit: Ignore the error message(s), and restart the computer.
Code
Description
062 Boot failure-default configuration used
Default configuration in use
101 System Board Failure
Interrupt controller failure
102 System Board Failure
Timer 2 test failure
106 System Board Failure
Diskette controller failure
151 System Board Failure
Real-time clock failure
161 Bad CMOS Battery
Dead battery
162 Configuration Change Has Occurred
Configuration error
162 Configuration Error
CMOS checksum error
163 Date and Time Incorrect
Real-time clock is not updating
164 Memory Size Error Memory size error
201 Memory Size Error
Memory data error
1780 Hard Disk Error
Fixed disk 0 failure