Panasonic WJHD100 Instrukcje Operacyjne

Przeglądaj online lub pobierz Instrukcje Operacyjne dla Sieciowe rejestratory wideo (NVR) Panasonic WJHD100. Panasonic WJHD100 Operating Instructions Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
Before attempting to connect or operate this product,
please read these instructions carefully and save this manual for future use.
Model No. WJ-HD100
Digital Disk Recorder
Operating Instructions
Digital Disk Recorder WJ-HD
OPERATE
TIMER
HDD
ALARM
SUSPEND
SUMMER
TIME
FULL
LOCK
MEMORY CARD
DISPLAY SELECT
STOP
LCD CONTRAST
PLAY
SETUP/ESC
REC
PUSH
PAUSE
SET
ALARM SEARCH
STEP
REW/FF
MODE SELECT
/
/
/
/
ENGLISHDEUTSCH
FRANÇAIS
ESPAÑOL
Przeglądanie stron 0
1 2 3 4 5 6 ... 49 50

Podsumowanie treści

Strona 1 - WJ-HD100

Before attempting to connect or operate this product,please read these instructions carefully and save this manual for future use.Model No. WJ-HD100Di

Strona 2 - ENGLISH VERSION

10CONNECTION Basic ConnectionTo select the recording mode from an external device connected to the EXT REC mode switch, the JOG/EXT REC parameter int

Strona 3 - CONTENTS

11 Connections with PS•Data EquipmentPS•Data equipment must be set up for communication as follows:• Protocol selection: PS•DATA• Unit Address: Set a

Strona 4 - FEATURES

12Recommended video multiplexers are Panasonic’s WJ-FS series or similar models having specifications as follows.• Switching recognition signal is loc

Strona 5 - PRECAUTIONS

13 RS-232C ConnectionUse an RS-232C cable (not included) as shown below toconnect the RS-232C terminal with a personal computer orthe like. The proto

Strona 6 - ■ Front View

Mode Switch SettingThe 6-bit DIP switch on the rear panel is used as follows.#1 through #4: For setting the unit address or initializ-ing the setup

Strona 7 - ■ Rear View

15SETUP PROCEDURES Prior to Setup● Turning On the Power1. Plug the power cord into the AC outlet.2. Turn on the power switch on the rear panel.The op

Strona 8

16● Displaying the SETUP MENU1. Confirm that the camera and peripherals are connected correctly and securely.2. Turn on the power switches of all syst

Strona 9 - ● Warning

17● Setup Menu SequenceThe WJ-HD100 provides the following seven setup menus: WJ-HD100 SETUP MENU, SYSTEM SETUP, REC SETUP, ALARMSETUP, INTERNAL TIMER

Strona 10 - CONNECTION

18 InitializingYou can either initialize all disk contents including imagedata and setup data, or setup data only.● Initializing All Contents & S

Strona 11 - Data Equipment

19 WJ-HD100 SETUP MENU● Clock Setup 001 CLOCK>Set the internal timer to the present time and date.The default value is “1.JAN00 0:00”.1. Hold down

Strona 12 - ■ Series Connection

2ENGLISH VERSIONThe serial number of this product may be found on the bot-tom of the unit.You should note the serial number of this unit in the spacep

Strona 13 - GGGGGGGGGGG

2. Select the desired position with the JogDial. The defaultis R-LOWER.L-UPPER: Displays time & date in the left upper corner.R-UPPER: Displays ti

Strona 14 - ● Alarm Output Polarity

211. Move the cursor to STATUS POSI. with the [▲] or [▼]button.2. Select the desired position with the JogDial. The defaultis R-LOWER.L-UPPER: Display

Strona 15 - ● Turning Off the Power

● Password Setup102 PASSWORD LOCKA 5-digit password is entered to protect all settings, record-ed pictures, and operating status, or settings only fro

Strona 16 - ● Displaying the SETUP MENU

23● Set Time108 SET TIMEThis setting specifies the hour for the master unit to supplythe Time Adjust OUT signal to the slave units once a day.You need

Strona 17 - ● Setup Menu Sequence

● Recording Field Rate 202 REC RATEThe field rate or number of fields per second can be select-ed in SP mode. The higher the field rate, the more info

Strona 18 - ● Initializing Setup Data

25● Disk End Mode Setup204 DISK ENDThe menu offers the following four options at the point where the available recording space on the disk is used up:

Strona 19 - 002 TIME&DATE TYPE

[ON]: Enables the buzzer beep at the disk end (remain-ing space 0 %).[OFF]: Disables the buzzer beep.● Jog Click Terminal Definition206 JOG/EXT RECThe

Strona 20

271. Move the cursor to DURATION with the [▲] or [▼] but-ton.2. Select the desired duration with the JogDial. The default value is 10 seconds.The unit

Strona 21 - 101 FWD/REW MODE

Notes: • VMD should be used with an ordinary camera input tothe unit. Select [OFF] to avoid useless VMD when avideo multiplexer or combination camera

Strona 22 - 105 KEYLOCK BUZ

29● Making Reservations1. Move the cursor to the desired day line with the [▲] or[▼] button.Move the cursor to the D (bottom) line when a dailybasis r

Strona 23

3CONTENTSPREFACE ... 4FEATURES ...

Strona 24 - ■ REC SETUP

1. Move the cursor to UNIT ADDRESS with the [▲] or [▼]button.2. Select the address with the JogDial. The default value is 1.From 1 to 96: Set an addre

Strona 25 - 204 DISK END

312. Select the bit length with the JogDial. The default value is 8 bits.7: 7 bits 8: 8 bits; select 8 when using the PS•DATA protocol.● Parity Check

Strona 26

33Password VerificationPause/Playback Skip PlaybackBackwardForward..32Stop Recording (Capacity) Recording (Mode)Upward or downwardWhen a button is pre

Strona 27 - ■ ALARM SETUP

Note: A reserved recording will interrupt playback and startat the reserved start time.● Power-on RecordingFor power-on recording select [EXT] in the

Strona 28 - 306 VMD SETUP

35Alarm recording stops depending on the settings made inthe ALARM SETUP menu as follows:• If DURATION is selected, recording stops when thepreset tim

Strona 29 - ● Making Reservations

3. Rotate the JogDial clockwise to advance to the nextlater field or counter-clockwise to rewind to the nextolder.4. Press the [ STOP] button to stop

Strona 30 - ■ COMMUNICATION SETUP

374. Press the [B PLAY] button to play it back.Note: Make certain to rotate the JogDial one click at atime.● Alarm History SearchT: Alarm terminal was

Strona 31 - ■ SYSTEM INFORMATION

● Alarm History SearchThe alarm history is listed on the monitor in chronologicalorder with event number, date, time, availability of recordedpicture,

Strona 32 - OPERATING PROCEDURES

39 Copy to CompactFlash CardThe pictures recorded on the hard disk can be copied to aCompactFlash card for browsing on a personal computer.The pictur

Strona 33 - ● Internal Timer Recording

5. Press the LCD button to the right or left to specify thenumber of pictures to be copied.1: The picture frozen on the monitor is copied to thecard.8

Strona 34 - ● Step Playback

4TRADEMARKSSanDisk and CompactFlash are trademarks of SanDisk Corporation.Microsoft and Windows are either registered trademarks or trademarks of Micr

Strona 35 - ● Alarm Record Search

41Try again when Password Error appears on the LCD, orpress the LCD button to quit password verification.● Enabling Button Lock1. Press the LCD button

Strona 36 - ● Alarm History Search

Alarm recording does not function in asystem including a video multiplexer.The ALARM IN signal has the wrongpolarity for the WJ-HD100.Setup menus supp

Strona 37 - ● Suspending Alarm Input

43SPECIFICATIONSGeneralRequired Power: 220 - 240 V AC 50 HzPower Consumption: 22 WOperating Temperature: +5°C to +45°C (41°F to 113°F)Dimensions: 420

Strona 38 - ● Resetting Alarm

ItemSHIFTSETUPFUNCTIONStep Playback REW.To Play/Stop SelectedAlarm RecordTo Show/Hide SETUPMENUThe top of the oldest record will beaccessed.Jump to Ol

Strona 39 - ● Folders and Files

45OFF, INT or EXT selectableSUMMER TIMEOperate LCD Button.Item WV-CU360WJ-HD100 NoteSUMMERTIMESHIFTSETUPFUNCTION31Timer REC ModeSelectionSHIFTSETUPFUN

Strona 40 - ● Password Verification

462. Escape from the prompt mode on the first unit.Press the STOP button on the unit you wish to begin recording. The FULL indicator on the unit will

Strona 41 - TROUBLESHOOTING

47 Communication ProtocolThe following pages detail the elements for communication between the Digital Disk Recorder and the personal computer.Make c

Strona 42 - SPECIFICATIONS

48● Command TableBasic OperationItem Transmission Command (ASCII) Response (ASCII) Parameter (ASCII)Fast Forward to the end OFF OFFPause OPA OPAPlay O

Strona 43 - APPENDIX

49Miscellaneous ControlItem Transmission Command (ASCII) Response (ASCII) Parameter (ASCII)Playback Speed LTM:n LTM n=0-Fn=0 11 ... Fastestn

Strona 44 - ● Loop Connection Recording

50InquiryItem Transmission Command (ASCII) Response (ASCII) Parameter (ASCII)Remaining Size QHR QHR:nnn nnn=000-100 Decimal %InquiryID Inquiry QID Q

Strona 45 - ● Playback

5PRECAUTIONS• Refer all work related to the installation of this productto qualified service personnel or system installers. • Avoid condensation on t

Strona 46 - ■ Communication Protocol

Matsushita Electric Industrial Co., Ltd.Central P.O. Box 288, Osaka 530-91, Japan2000 © Matsushita Communication Industrial Co., Ltd. All rights reser

Strona 47 - ● Command Table

6MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS Front ViewOPERATETIMER HDDALARMSUSPENDSUMMERTIMEFULLLOCKMEMORY CARDDISPLAY SELECTSTOPPLAY RECPUSH– PA

Strona 48 - Media Control

7!7 REW/FF and Up Button [REW/FF 1/2] [D]Press this button to rewind or fast-forward the recordedfield. The LED lights in the REW/FF mode.Press this b

Strona 49

8#22 Status Out TerminalThese terminals supply the following status information:PLAY OUT, REC OUT, AUTO OFF OUT, DISK ENDOUT.AUTO OFF OUT: AUTO OFF OU

Strona 50 - Impreso en Japón

9 Mounting in the Rack1. Remove the four rubber feet by removing the fourscrews on the bottom of the unit.2. Place the rack mounting brackets on both

Komentarze do niniejszej Instrukcji