FRAMES section
Note:
• ThissectionisonlyusedforWV-SX850cagesdefinitions.
• CopyeachvaluebasedontheexistingWJ-MPU850/855's"sys.ini"file.
[FRAMES]
***{ MX Frame definition from Admin file }
***{MXSWhasformat<num_rows>,<num_cols>,<interface_num> }
***{Allothersuse<num_functions>,<interface_num> }
MXSWFunction=8,4,0
MXCONTFunction=8,0
MXOSDFunction=2,0
MXDIOFunction=2,0
MXRMSFunction=0,0
PROCS section
This section tells the system which interface is to be used by certain process files.
[PROCS]
***{ Process Interface Assignments }
***{Format:<ProcessName>=<interface_num> }
***{Setthesethreetotheinterface_numoftheEthernetkeyboards: }
Keybp=1
Mxconts=1
Mxpfw=1
"1" means interface1 in [INTERFACES] section. WV-ASC970 Server has 3 software processes (listed
above) to communicate to a CU950. All processes should use same interface number. Factory default
setup is interface "1".
***{SetSwcputothesameinterface_numforallunitCPUs: }
Swcpu=0
"0" means interface0 in [INTERFACES] section. In case of Redundant System, Both CPUA and CPUB
must be assigned the same interface_num. Factory default setup is interface "0".
***{SetUnitManagertothesameinterface_numforallsystemCPUs:}
UnitManager=0
***{SetCSntptotheinterface_numforEXTERNALSNTPoperation: }
CSntp=0
Not currently supported
***{SetSSntptothesameinterface_numforallsystemCPUs: }
SSntp=0
Not currently supported
OSD section
All settings in this section are set to factory default, which provide the best monitor layout.
[OSD]
***{ Initial OSD display position }
***{ Alarm text is placed on the General Status line. }
***{Format:<DisplayItemPosition>=<x-position>,<y-position> }