7. Timer
The timer function is used to programme and automati-
cally activate Tour or Group Sequences according to
the time of day and day of the week.
There are sixteen (16) timers available in one day.
8. Alarm
8-1. Alarm Input
1. Camera Site Alarm
This alarm signal is supplied from the associated
camera site receiver or camera.
Receivers capable of camera site alarm input are
models WV-RC100, WV-RC150 and WV-RC170.
2. Interface Alarm
This alarm signal is supplied from the Alarm Input
Connector (ALARM IN) on the rear of the Switcher.
Up to thirty-two (32) alarm inputs are available.
3. Video Input Signal Loss Alarm
This alarm is indicated that camera signal loss has
occurred.
4. PC Command Alarm
This alarm is the received command from the
Personal Computer.
8-2. Alarm Operation Mode
There are three alarm operation modes available in the
WJ-SX350 Matrix Switcher.
The alarm modes can be switched according to the
time programmed on the internal timer.
Examples of these modes are given below.
Alarm Mode 1: Any alarmed pictures are assigned to Monitor 1.
Mode 1 displays all alarms on Monitor 1.
If more than one alarm is activated, the system will sequentially display the alarms on Monitor 1.
Alarm Mode 2: Any alarmed pictures are assigned to four Monitors (1 - 4).
Mode 2 displays the first alarm on Monitor 1. When the second alarm is received, the first alarm is shifted to Monitor 2
and the second alarm is displayed on Monitor 1 and so on. This means, the latest alarm is always displayed on Monitor
1. If more than four alarms are activated, the system will sequence the pictures starting with Monitor 1, then 2, etc.