Panasonic WJSX350 Instrukcje Operacyjne Strona 41

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 68
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 40
-39-
Cautions:
To prevent unauthorized access, be sure to
change the Password preset at the factory.
If an operator's level for access to the item
“SETUP MENU” or “OPERATOR” on the LEVEL
TABLE has not been registered, that operator
will not be allowed access to the SETUP MENU
a second time.
5. Move the cursor to the OPERATOR parameter by
moving the Joystick Controller, then press the CAM
(SET) button to display the table for the selected
operator shown below.
R E G I S T R A T I O N
O P E R A T O R = 0 0 ( T I M E R )
L E V E L = 1
P R I O R I T Y = 8
P A S S W O R D = 1 2 3 4 5
P R O G. C L E A R = S E T
C A M S E L E C T ( O P = 0 0 )
CAM
CAM
CAM CAM
0 1 0 5 0 9 1 3
0 2 0 6 1 0 1 4
0 3 0 7 1 1 1 5
0 4 0 8 1 2 1 6
:
V & P / T
:
V
: –
C A M S E L E C T ( O P = 0 0 )
CAM
CAM
CAM CAM
1 7 2 1 2 5 2 9
1 8 2 2 2 6 3 0
1 9 2 3 2 7 3 1
2 0 2 4 2 8 3 2
:
V & P / T
:
V
: –
2. REGISTRATION (Operator Registra-
tion)
This table is used to establish operator numbers for the
users of the system along with associated passwords,
operator levels and priorities.
Up to fifteen (15) operators may be registered.
Additionally, operator limits for camera access are on
this table.
Select REGISTRATION on the OPERATOR menu by
pressing the Joystick Controller, then press the CAM
(SET) button to display the REGISTRATION menu as
shown below.
6. Move the cursor to each camera on the table by
moving the Joystick Controller, then select the
desired operator limit by pressing the +1CAM INC
or –1CAM DEC button.
P: Enables Video and Pan/Tilt Control
: Enables only Video Control
: Disables Control
Note: The table for Operator 16 cannot be edited.
7. When satisfied with the programmed operator limits
on this page, press the HISTORY FWD button to
select the next page.
Repeat the above procedures until all limits are pro-
grammed.
8. Press the HISTORY BACK button to go back to the
previous page.
9. When satisfied with all limits, press the MON (ESC)
button to return to the previous REGISTRATION
menu.
10. Similarly, repeat the above procedures to register
all other operators.
To programme or edit the Operator Registration table,
do the following:
1. Move the cursor to the OPERATOR parameter by
moving the Joystick Controller. Then enter an
Operator Number between 1 and 15 by pressing
the Numeric Buttons or the +1CAM INC or –1CAM
DEC button.
2. Move the cursor to the LEVEL parameter by moving
the Joystick Controller. Then enter a Level Number
between 1 and 3 by pressing the Numeric Buttons
or the +1CAM INC or –1CAM DEC button.
3. Move the cursor to the PRIORITY parameter by
moving the Joystick Controller. Then enter a Priority
Number between 1 and 8 by pressing the Numeric
Buttons or the +1CAM INC or –1CAM DEC button.
4. Move the cursor to the PASSWORD parameter by
moving the Joystick Controller. Then enter a 5-digit
Password Number by pressing the Numeric
Buttons.
Notes:
Operator 00 is allotted for the Timer. Initially,
priority 8 is selected at the factory.
When using the TIMER EVENT function prefer-
entially in the system, it is recommended to set
PRIORITY higher level (smaller numbers).
For manual operation of the system by an oper-
ator, set PRIORITY to a lower level (larger num-
bers).