x Connect an external amplifier-embedded speaker to the audio output cable (for use of the
audio transmission function).
Connect a stereo mini plug (ø3.5 mm) (Audio output is monaural.).
• Recommendedcablelength:Lessthan10m{32.8ft}
c Connect the alarm input/output cable.
<Ratings>
Terminal name Ratings
ALARM OUT, AUX OUT Open collector output (maximum applied voltage: 20 V DC)
Open 4 V DC - 5 V DC by internal pull-up
Close Output voltage 1 V DC or less (50 mA or less)
ALARM IN, DAY/NIGHT IN Non-voltage make contact input (4 V DC - 5 V DC, internally pulled
up)
OFF Open or 4 V DC - 5 V DC
ON Make contact with GND (required drive current: 1 mA or more)
Note:
• Checkifratingofanexternaldevicesuchasasensorisapplicabletotheratingofthisproduct
by referring to the provided operating instructions.
Specification of 4P alarm cable (accessory)
GND (black)
AUX OUT (gray) (Terminal 3)
ALARM OUT (red) (Terminal 2)
ALARM IN, DAY/NIGHT IN (green) (Terminal 1)