Panasonic PAW280MAH2 Instrukcje Operacyjne Strona 9

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 74
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 8
9
General information and safety instructions
Prevent the refrigerant gas from coming into contact with a fan heater, stove,
range, or other source of re.
Incorrectinstallationcanresultinfallingequipmentcausingdamage,injuriesorother
accidents.
Install in a location that is fully strong enough to support the weight of the
equipment.
Perform installation that is secure enough to withstand earthquakes, whirlwinds,
storms and other strong winds.
Frostbite injuries may result from coming into direct contact with the refrigerant gas.
When handling refrigerant gas, be careful not to touch the refrigerant gas
directly.
CAUTION
The following precautions need to be followed strictly, in order to avoid hazardous situations,
which could result in minor or moderate injury.
Electricshock,shockandresmayresultfromincompletegroundingoftheequipment
or failure to install an earth leakage breaker.
Be sure to ground equipment properly.
Do not attach ground wires to gas pipes, water pipes, lightning arresters, or
telephone ground lines.
Always install an earth leakage breaker.
Ignitionofammablegasorinammablematerialsmayresultfrominstallingthesystem
inlocationswhereammablegascangenerate,enter,buildup,orleak.
Do not install the system in locations where ammable gas can occur in any
way.
Do not install in locations where volatile inammable materials are handled.
1.4 Warranty policy
We can be held responsible for the quality and performance of the AHU Kit we supply.
However, we cannot be held responsible for the performances, operations and machine controls
of your complete AHU system which incorporates our AHU Kit, nor for the components used in
the refrigerant cycle of your AHU system (including, but not limited to, compressors, high-pres-
sure switches, check valves, strainers, expansion valves, solenoid valves, 4-way valves, capil-
lary tubes, accumulator tanks, and heat exchanger tubes), nor for any damages and defects
caused in the process of installing our AHU Kit, by the system design and/or during assembly of
your AHU system.
We do not publish the certicate to show conformity to the EMC and the product safety require-
ments applicable to your complete AHU system.
Przeglądanie stron 8